<p><a href="https://pchlavka.cz/1-gsm-sms-power-alarm-zarizeni-posle-sms-pri-ztrate-napajeni-baterie-na-8-hodin-operozu-monitoring- temperature-and-humidity.html" target="_blank" class="ext" rel="noreferrer noopener">CAN BE PURCHASED HERE .....................< /a><span class="ext"></span></p>
<p></p>
<p><strong>Function description - monitoring of power supply, temperature and humidity</strong></p>
<p><strong><span style="background-color: #ffffff;">The device will send an sms when there is a power failure, the device is backed up by a battery so that it can send notifications without power.<br />Furthermore, the device can be set to that if the sensor detects a value outside the set range (temperature or humidity, it will send an SMS)</span></strong></p>
<p></p>
<p><span style="background-color: #ffa500;">Need to charge.................2-8 hours</span></p>
<p></p>
<p>For example, we have a set range of -5 to +19 <span class="ILfuVd yZ8quc">°C</span>, the device will send an sms at -4 <span class="ILfuVd yZ8quc">°C </span>and 20 <span class="ILfuVd yZ8quc">°C</span> etc</p>
<p></p>
<p><strong>Instructions:</strong></p>
<p>Insert the green patch panel into the RTU5023 base unit<br />Connect the cables to the green patch panel (view from top left to right)</p>
<p></p>
<p>power supply</p>
<p>red power cable +</p>
<p>black power cable -</p>
<p></p>
<p>sensor</p>
<p>white GND cable</p>
<p>black Data cable</p>
<p>red VCC cable</p>
<p></p>
<p>Some sensors are tested - then the cables to the sensor are connected - it happened that the sensors did not seem to work, but it was the contact</p>
<p>Please charge the internal battery (12-24 hours) before testing</p>
<p></p>
<p>white GND cable</p>
<p>black Data cable</p>
<p>red VCC cable (sometimes it happens that one of the three contacts does not connect and the module reports zero values)</p>
<p></p>
<p>Example..<br />Armed<br />Temp:00.0C Normal<br />Humi:00RH% Normal<br />Volt:12.4VDC Normal</p>
<p></p>
<p><img alt="" src="http://servishlavka.cz/sites/default/files/images/2018-06-11%2011_26_14-GSM%20SMS%20Power%20Alarm%20Za%C5%99% Battery %20na%208%20hodin%20.jpg" style="width: 250px; height: 139px;" /></p>
<p>Unscrew the back cover and insert the SIM card (format <a href="https://www.o2.cz/osobni/casto-kladene-otazky/434455-faq_11.html" target="_blank" class="ext" rel="noreferrer noopener">minisim</a><span class="ext"></span>, <a href="https://www.google.com/search?q=how+to+disable+pin&amp; ie=utf-8&amp;oe=utf-8&amp;client=firefox-b" target="_blank" class="ext" rel="noreferrer noopener">pin disabled</a><span class="ext">< /span>)</p>
<p>Screw the antenna and turn the Power Switch under the SIM card to the right position.</p>
<p><a href="http://servishlavka.cz/kh/sites/default/files/sim_1.png"><img alt="" src="http://servishlavka.cz/kh/sites/ default/files/sim_1.png" style="width: 600px; height: 314px;" /></a></p>
<p>Connect the adapter to the electrical socket. network 220 V</p>
<p></p>
<div dir="ltr">GSM LED indicator<br /><span lang="en" xml:lang="en"><span>LED flashing</span> <span>for</span> <span> 0.8</span> <span>seconds</span> <span>(</span><span>fast</span><span>)</span><span>:</span> <span> registration</span> <span>to</span> <span>GSM network. (after about 10 s the device should register to the GSM network)</span></span></div>
<div dir="ltr"><span lang="en" xml:lang="en"><span><span lang="en" xml:lang="en"><span>LED Flashing</span> about 3 <span>seconds</span> <span>:</span> normal status of the <span>GSM network.</span></span></span></span><br /><span lang= "cs" xml:lang="cs">LED off<span>:</span>          <span>Unable to connect</span> <span>to SIM card or</span> <span>not registered</span> <span>to mobile network</span></span></div>
<p></p>
<h2>Next, the device is set up using SMS - we send an SMS from our phone to the SIM card in the device</h2>
<p><span style="color: #ff0000;"><strong><span lang="en" xml:lang="en">Time setting 1234D2018-06-11T10:09# </span></strong ></span></p>
<p>(we will edit the sms according to the current time 2018 year, 06 month, 11 day of the month, 10 hour, 09 minute)</p>
<p></p>
<p><strong>Mobile phone authorization (phone is 776190060 - example, messages will be sent to this phone)</strong><br />1234A01T776190060</p>
<p>Who didn't get it 776190060 = Your mobile number</p>
<p></p>
<p><strong>Authorization of a mobile phone with an international prefix, we add two zeros before 420, i.e. 00420 (the phone is 776190060 - example, messages will be sent to this phone)</strong><br />1234A01T00420776190060</p>
<p></p>
<p><strong>Authorization of another mobile phone (the phone is 776190061 - example, messages will be sent to this phone)</strong><br />1234A0<span style="background-color: #00ff00;">2< /span>T776190061</p>
<p>etc...</p>
<p></p>
<p><strong>Restart after 12 hours </strong></p>
<p>1234REBOOT12</p>
<p></p>
<p><strong>Restart manual</strong></p>
<p>1234RT</p>
<p></p>
<p><strong>For notifications in the event of a power failure, nothing further needs to be set ............................................</strong><br /> </p>
<p><span style="color: #0000ff;"><strong><span style="background-color: #d3d3d3;">Sends an sms when the power is turned off (after about 80 seconds without power)</span>< /strong></span></p>
<p><span style="color: #0000ff;"><strong><span style="background-color: #d3d3d3;">Volt:00.0VDC Lower</span></strong></span>< /p>
<p></p>
<p><span style="color: #0000ff;"><strong><span style="background-color: #d3d3d3;">Sends sms when power is restored</span></strong></span>< /p>
<p><span style="color: #0000ff;"><strong><span style="background-color: #d3d3d3;">Volt: 12.5VDC Normal</span></strong></span>< /p>
<p></p>
<p>Sends status after ringing from an authorized number</p>
<p></p>
<p>Armed<br />Temp:24.3C Normal<br />Humi:68RH% Normal<br />Volt:12.5VDC Normal<br />GSM Signal Value:21<br />Imei:869103024282941</p >
<p></p>
<p><strong>Setting the temperature range</strong></p>
<p>1234AINR1L-050H260#  Sends a message if the temperature is less than -5 C and greater than 26 C</p>
<p></p>
<p><strong>Setting the humidity range</strong></p>
<p>1234AINR2L005H098# Sends a message if the humidity is less than 5% and greater than 98%</p>
<p></p>
<p><strong>Set voltage range</strong></p>
<p>1234AINR3L080H130#  Sends a message if the voltage is less than 8V and greater than 13V</p>
<p></p>
<p><strong>Turn off the daily report (if you don't want to send the status every day - <span style="background-color: #ffff00;">report is sent by rtu5023 in the basic setting</span> - if you don't want the daily report, send an sms below )</strong></p>
<p><span style="background-color: #00ff00;">1234DRTDEL</span><br /> </p>
<p><strong>Reset (setting default values)</strong></p>
<p>1234RESET</p>
<p></p>
<p>Turn off messaging</p>
<p><span style="background-color: #00ff00;">1234BB</span></p>
<p></p>
<p><strong>Alarms yes - will send messages</strong></p>
<p>1234AA</p>
<p></p>
<p>Default password is 1234 Change password command 1234P6666 (Change password 1234 to 6666)</p>
<p></p>
<p>Other settings<br />1234DT001     Send status every hour<br />1234DT008     Send status every 8 hours etc..</p>
<p></p>
<p>Deletion of the number in the 3rd position</p>
<p><b>1234D</b><b><span style="color: #000099;">A03</span></b><b>T00420776190060</b></p>
<p></p>
<p><b>List of all authorized numbers 1234A03T008613570810254</b></p>
<p></p>
<p></p>
<p></p>
<p>set the time according to the operator</p>
<p><b>1234TEL<b>00420776190060</b>#</b></p>
<p><b> </b></p>
<p><b> password 1234<br />tel 776190060<br />area code 00420</b></p>
<p></p>
<p>In case of problems, reset the device .... factory reset the device<br /> </p>
<div dir="ltr"><span style="color: #ff0000;"><span lang="en" xml:lang="en"><span style="font-size: 10pt; font-style: normal; font-variant: normal;"><b><span lang="en" xml:lang="en"><span style="font-size: 10pt; font-style: normal; font-variant: normal ;"><b>Reset the device - Slider to the OFF position - press the reset button under the sim card and hold - slider to the ON position - release the reset button after 10 seconds</b></span></span></b> </span></span></span></div>
<div dir="ltr"><span style="color: #ff0000;"><span lang="en" xml:lang="en"><span style="font-size: 10pt; font-style: normal; font-variant: normal;"><b><span lang="en" xml:lang="en"><span style="font-size: 10pt; font-style: normal; font-variant: normal ;"><b>After the reset, the device is set to basic settings</b></span></span></b></span></span></span></div>
<p></p>
<p></p>
<p>For individual settings or consultation, you can write to <a href="mailto:info@pchlavka.cz?subject=nastaven%C3%AD%205023" class="mailto">info@pchlavka.cz</a ><span class="mailto"></span><br />Or call tel. 776190060</p>
<p></p>
<p><a href="https://pchlavka.cz/1-gsm-sms-power-alarm-zarizeni-posle-sms-pri-ztrate-napajeni-baterie-na-8-hodin-operozu-monitoring- temperatures-and-humidity.html" target="_blank" class="ext" rel="noreferrer noopener">Link to the product https://www.pchlavka.cz/posle-SMS-po-ztrate-napajeni</a ><span class="ext"></span></p>
<p></p>